Quantum LTO-2 User Manual

Page of 94
Chapter 5  Specifications
Power Specifications
38
LTO-2 Half-Height Tape Drive User’s Guide
Power Specifications
5
The desktop LTO-2 Half-Height Tape Drive comes with a built-in 90-
260VAC (47-63 Hz) automatic switching power supply. 
Maximum voltage and power specifications for the internal LTO-2 
Half-Height Tape Drive are listed in 
.
Table 5   Voltage and 
Current
 
Table 6   Power 
Dissipation
        
Specification
+12 VDC
+ 5VDC
DC Voltage Tolerance
 (1)
12.00 + or – 10%
5.00 + or – 5%
Non-operating max voltage
14 Volts peak
7 Volts peak
Idle current
 (1)
0.13 amps RMS
1.4 amps RMS
Standby current (max)
 (2)
0.45 amps RMS
1.4 amps RMS*
Typical operating current 
(3)
0.71 amps RMS
2.9 amps RMS
Max operating current
 (4)
0.83 amps RMS 
3.0 amps max RMS
Max. Peak operating 
current
 (5)
2.34 amps
(1 sec max)
3.0 amps max RMS
Ripple (peak-to-peak)
< 100 mV
< 100 mV
* RMS parameters measured at the power connector using a true RMS 
digital meter.
Specification
LTO-2
Idle Power
 (1)
9 watts RMS
Standby Power 
(2)
12.5 watts RMS* 
Typical Operating Power 
(3)