Adaptec 58300 User Manual

Page of 88
Chapter 5: Installing the HostRAID Controller and Disk Drives
27
Installing the Controller to a SAS Expander
You can use a SAS edge expander to connect multiple disk drives to your HostRAID controller 
or multiple controllers. Commands can be sent down one link and data returned on another in 
a separate connection to increase fault tolerance. Using a SAS expander and dual-port SAS 
drives and SATA drives with 2-port adapters, you can design redundant systems for maximum 
fault-tolerance. 
To install the HostRAID controller to a SAS expander:
1
Using the appropriate cable, connect the HostRAID controller to a PHY connector on the 
expander.
2
Connect a cable from a PHYconnector on the expander to a disk drive. 
Next Steps
If you are installing the driver and an operating system onto a bootable array, continue with 
If you are completing a standard installation onto an existing operating system, continue with 
Internal SAS connector
SAS fan-out cable
External SAS 
connector