4.2.1. Setting-up of ADDRESS 
SW9
 
1.  Unscrew two screws on bottom side of the keyboard and remove bottom cover. 
2.  Push switch SW9 on PCB bottom side; backlight LED’s are switched Off to indicate Set 
Address Mode. 
3.  Button LED’s indicate ADDRESS in binary code – Button 1 bit 0, Button 2 bit 1 etc… Push 
buttons to toggle address bits to requested value of ADDRESS (see examples on the picture 
below). 
4.  Push switch SW9 to save ADDRESS to non-volatile memory and to enter keyboard Standard 
Mode - backlight LED’s are switched On to indicate Standard Mode. 
5.  Assembly the control panel. 
 
 
4.2.2. Troubleshooting 
Flashing backlight LED’s means non-volatile memory ERROR. Try Power OFF – Power ON sequence 
to restart device and set ADDRESS again. 
4.2.3. Display ADDRESS 
Press and hold Button 1 while powering On. Button LED’s indicate ADDRESS in binary code – 
Button 1 bit 0, Button 2 bit 1, .... After 10 sec keyboard continues normal operation. 
4.2.4. Display Firmware version 
Press and hold Button 2 while powering ON. All LED’s flashes 5 times – FW version 1.05. After 10 sec 
keyboard continues normal operation. 
 
 