Seagate ST9100826A User Manual

Page of 56
Momentus 5400 FDE Product Manual, Rev. C
35
4.1.7
Identify Device command
The Identify Device command (command code EC
H
) transfers information about the drive to the host following 
power up. The data is organized as a single 512-byte block of data. All reserved bits or words should be set to 
zero. Parameters listed with an “x” are drive-specific or vary with the state of the drive. See Section 2.0 on 
page 5 
for default parameter settings.
The following commands contain drive-specific features that may not be included in the Draft ATA-7 Standard.   
  
      
Word
Description
Value
0
Configuration information:
 
• Bit 15: 0 = ATA; 1 = ATAPI
 
• Bit 7: removable media
 
• Bit 6: removable controller
 
• Bit 0: reserved
0C5A
H
1
Number of logical cylinders
16,383
2
ATA-reserved
0000
H
3
Number of logical heads
16
4
Retired
0000
H
5
Retired
0000
H
6
Number of logical sectors per logical track: 63
003F
H
7–9
Retired
0000
H
10–19
Serial number: (20 ASCII characters, 0000
H
 = none)
ASCII
20
Retired
0000
H
21
Retired
0400
H
22
Obsolete
0000
H
23–26
Firmware revision
 
(8 ASCII character string, padded with blanks to end of string)
x.xx
27–46
Drive model number (40 ASCII characters, padded with blanks 
to end of string)
ST9120826A
 
ST9100826A
 
ST980821A
 
ST960814A
 
ST940811A
47
(Bits 7–0) Maximum sectors per interrupt on Read multiple and 
Write multiple (16)
8001
H
48
Reserved
0000
H
49
Standard Standby timer, IORDY supported and may be disabled
2F00
H
50
ATA-reserved
4000
H
51
PIO data-transfer cycle timing mode
0200
H
52
Retired
0200
H
53
Words 54–58, 64–70 and 88 are valid
0007
H
54
Number of current logical cylinders 
xxxx
H
55
Number of current logical heads 
xxxx
H
56
Number of current logical sectors per logical track
xxxx
H
57–58
Current capacity in sectors
xxxx
H