SSI America 8040 User Manual

Page of 98
 
Super Systems Inc. 
Page 41                      SDS Data Logger Manual #4565 Rev D 
 
 
Figure 2.3 Report Properties Report tab 
 
Clicking on the open box, 
, next to the “Data” field will display a screen from which the user can 
select the interval time (ten seconds, twenty seconds, thirty seconds, one minute, two minutes, or five 
minutes) and also the specific survey to use (figure 2.4).  This screen will only display survey data that 
has already been downloaded (SDS 
→ Download Surveys and Data). 
 
Figure 2.4 Load Survey Data screen 
The default interval is one minute.  Select the survey to use and click on the “Use” button.  Information 
included with the data sources is: Template Name, [Company Name - Furnace Id], (Survey box Serial 
number), and the date/time range of the survey data.  Any manual entries will have [Manual Entry] at 
the beginning.  See the section 
Manually Creating a Survey Record
 for information on how to add a 
survey record manually.  Clicking on the open box next to the “Report Template” field will open a dialog 
box from which the user can select the specific report template to use for the report.  The software will 
open the dialog box in the “SDSReportTemplates” folder (typically C:\SSi\SDS\ReportTemplates) for 
existing report templates to use.  The “Report Heading / Title” field is for the heading or title of the