Sony SF-10000 User Manual

Page of 382
Status tab  
The Status tab allows you to specify preferences for displaying information in the status bar.  
Item 
Description 
Default frames per second 
The default frame rate used to calculate frame values. 
Frame values are useful when trying to synchronize sound with animation. Most animation players 
specify a playback frame rate at which video frames are shown to the user. If you are using an animation 
that has a frame rate of 15.0 frames per second, you would set the frame rate to 15.0. When status 
values are displayed, they will be shown in values of frames. This allows you to find the frame to which a 
given point in the sound file corresponds. 
Default beats per measure 
The number of beats in each measure for displaying in measures and beats. For example, 2/4 time 
would have two beats per measure. 
This setting will be also be used in the Edit Tempo dialog. 
Default beats per minute 
The number of beats per minute, that is, the tempo of a song for displaying lengths. 
This setting will be also be used in the Edit Tempo dialog. 
RMS level scan time 
The amount of sound data surrounding the cursor used to calculate the RMS level in the Levels toolbar. 
Peak level scan time 
The amount of sound data surrounding the cursor used when searching for a peak level to display in 
the Levels toolbar. 
0 VU (+4 dBu) level 
Choose a setting from the drop-down list or type a value in the box to calibrate the VU/PPM meters to 
their associated levels on the peak meters. 
VU meters display sound in dB VU, where 0 VU is a reference level, and there is headroom above 0 VU. 
The Sound Forge peak meters display peaks in dB FS (decibels relative to full scale). 
In digital audio, there is no headroom above 0 dB FS. Choosing a setting from this drop-down list 
subtracts a nominal dB value from the VU meters so that a signal displayed on the VU meters remains 
slightly below 0 dB on the peak meters. 
VU meter integration time  
Type a value in the box to set the amount of data surrounding the cursor that will be used to calculate 
levels in the VU meters. 
This setting has no effect on the PPM scales, which use fixed integration times: 
• UK  PPM:  10  ms  
•  EBU PPM: 10 ms 
•  DIN PPM: 5 ms 
•  Nordic PPM: 5 ms 
Toolbars tab  
The Toolbars tab allows you to specify which toolbars you want to display.  
Display or hide toolbars 
Select the check box to display a toolbar; clear a check box to hide a toolbar. 
Display or hide ToolTips 
Select the Show ToolTips check box if you want to display pop-up descriptions when the mouse is held over certain items. 
Customizing a toolbar 
1.  
From the View menu, choose Toolbars. The Preferences dialog appears with a list of available toolbars. 
2.  
Select the check box for a toolbar and click Customize. The Customize Toolbar dialog is displayed. 
3.  
Use the controls in the Customize Toolbar dialog to add, remove, or rearrange the buttons on the selected toolbar. Click Reset to 
restore the toolbar to its default setting. 
4.  
Click the OK button. 
320 
|
 CHAPTER 22