Troubleshooting Guide
If you experience difficulties when using your Verona, the following suggestions
may help resolve the problem.
IMPORTANT! 
The GOLDEN RULES for using a Master Clock:
 
The source equipment MUST be locked to the Master Clock.
 The 
Clock Frequency
 MUST match the sample rate(s) used in the system.
The unit fails to power up
  Ensure there is power available on the mains cable. Connect the power
cable, ensure it is pushed all the way in and press the 
Power
 button. If
there is a Power switch on the back panel, ensure this is set to the On (
I
)
position.
 
Check the rated supply voltage shown on the rear of the unit matches the
local supply voltage.
 
Check that the fuse has not blown - if so, correct any obvious cause then
replace the fuse as described on page 
The DAC/DDC suddenly mutes, Verona repeats its’ power-up sequence
 
This may be caused by short drop-outs or brown-outs on the AC supply.
When the disturbance has passed, normal operation should be restored.
 
Check for loose mains wiring.
The system fails to lock to Verona
  Check that the digital audio cables are of the correct type, correctly
connected and not damaged. Damaged cables are a VERY common cause
of malfunctions!
 Check 
that 
Verona is switched on and has settled for at least 1 minute.
 Check 
that 
Verona is set to the correct 
Clock Frequency
 (probably
44.1kHz
).
 
dCS Verdi and La Scala will only accept a 44.1kHz clock.
 
dCS Purcell will only lock if the 
WClk
 page is set to 
WClk:In
.
 
dCS Elgar Plus and Delius will only lock if the 
MS
 page is set to 
MS:Sync.
 
If you are using dCS Elgar Plus or Delius with Verona while upsampling to
176.4 or 192kS/s Dual AES or 88.2 or 96kS/s Single AES, you will need
software v4.30 or later for Elgar Plus or v2.30 or later for Delius.
 If 
Verona is locked to an 
Ext
ernal 
Ref
erence, ensure the reference
frequency is at a suitable frequency and the 
Couple
 menu is set to match
the external reference.
 If 
Verona is trying to lock to an 
Ext
ernal 
Ref
erence but is continuously
displaying 
Locking
, there is something wrong with the external reference
generator, the menu settings or the cable. The external reference may be
out of calibration, or at a frequency that the Verona cannot lock to.
 
AC coupled cables are not suitable for use with Word Clock signals.
Periodic clicks are heard from the loudspeakers
 
This is often caused by part of the system (usually the source equipment)
not being locked to the Verona, while the DAC is locked. Check that the
system is connected correctly, that the menu settings are correct and the
master clock frequency matches the sample rates in use.