HP (Hewlett-Packard) RX3600 User Manual

Page of 356
Dimensions and Values
lists the dimensions and values of the HP Integrity rx3600 for a rack- or pedestal-installed
configuration .
Table 2-2 Rack- or Pedestal-Installed Server Dimensions and Values
Value
Dimension
34-40.8 kg (75-90 lbs.)
Server weight (loaded product weight range
estimate)
Rack
69.6 cm (27.4 in.) x 44 cm (17.32 in.) x 17.24 cm (6.8 in.)
Rack dimensions (depth x width x height)
Max: 45.36 kg. (100 lbs.)
Rack weight
Server takes up 4U in a rack
Rack unit
Pedestal
69.2 cm (27.2 in.) x 36.9 cm (14.5 in.) x 51.2 cm (20.2 in.)
Pedestal dimensions (depth x width x height)
10.9 kg (24 lbs.)
Pedestal weight
44.9 kg. (99 lbs.)
Minimum standalone configuration
51.7 kg. (114 lbs.)
Maximum standalone configuration
Grounding
The site building shall provide a safety ground/protective earth for each AC service entrance to
all cabinets.
Install a PE (protective earthing) conductor that is identical in size, insulation material, and
thickness to the branch-circuit supply conductors. The PE conductor must be green with yellow
stripes. The earthing conductor is to be connected from the unit to the building installation earth
or, if supplied by a separately derived system, at the supply transformer or motor-generator set
grounding point.
Electrical Specifications
This section provides electrical specifications for the HP server.
System Power Specifications
Available power (output) is the maximum dc power that the power supply can supply to the
system.
Maximum input power is what the power supply requires from the AC line to deliver that
maximum DC output (given worst case efficiency and max loading)
Maximum input current is the worst case/highest current given the lowest input voltage and the
maximum input power
Table 2-3 System Power Specifications
Rating
Parameter
200-240 V ac
100-127 V ac
ac Voltage
1200 W
1200 W
Maximum dc Output Power
7A
1
14 A
1
Maximum System Input Current
47 to 63 Hz
47 to 63 Hz
Input frequency
48
System Specifications