HP (Hewlett-Packard) QR516B User Manual

Page of 89
A path policy of MRU (most recently used) does not maintain or reinstate balancing of I/O
load after a failover/failback multipath event. This could leave I/O in an unplanned for and
unbalanced state which may yield significant I/O performance issues. Implementation of an
MRU path policy is not recommended by HP.
NOTE:
If I/O is active to a LUN and an attempt is made to modify the path policy, a failure can
occur, indicating:
"error during the configuration of the host: sysinfoException;
Status=Busy: Message=Unable to Set".
If this problem occurs while attempting to change the path policy, reduce the I/Os to that LUN and
then try making the desired changes.
For additional information on this topic, refer to the chapter on "Multipathing" contained in the
VMware SAN Configuration Guide.
Configuring Round Robin Multipathing on ESX 4.x or later for Fibre Channel
With ESX version 4.0 and later, VMware supports a round-robin I/O path policy for active/active
storage arrays such as HP 3PAR StoreServ Storage. A round-robin I/O path policy is the preferred
configuration for ESX 4.0 and later; however, this path policy is not enabled by default for HP 3PAR
devices.
CAUTION:
If you are running Windows Server 2012 or Windows Server 2008 VM Cluster with
RDM shared LUNs, then individually change these specific RDM LUNs from Round Robin policy
to FIXED or MRU path policy.
, which is output from a Fibre Channel configuration, shows
a LUN with a path that has been set to Round Robin (VMware).
NOTE:
Note that each path status is shown as Active (I/O). The path status for an iSCSI
configuration would be the same.
Multipath Failover Considerations and I/O Load Balancing
39