SECTION 1 - INSTALLATION 
 
If you are going to use a telephone line with this controller, order it at least two weeks prior to the 
planned installation date.  This will assure that a phone line is available when the unit is installed.  
The telephone company will require the following information from you: 
 
Type: 
Touch Tone, Loop Start 
Ringer Equivalence: 
0.0 A 
Jack Type: 
RJ11C 
FCC Registration (US): 
DUF6VT-12874-OT-T 
DOC (Canada): 
1736 4528 A 
Electrical Listing: 
Complies with U.L. 294 - ETL Listed 
 
 
1.1 Installation 
Guidelines 
1.  Open the cabinet of the access controller and disconnect the keypad ribbon cable from 
the main circuit board. 
2.  Remove the 6-32 x 1/2 round head screws from the right side of the circuit board. 
3.  Remove the circuit board by gently pulling it out of the main terminal edge connector.  
CAUTION - the circuit board contains static sensitive components.  Discharge any static 
electricity from your hands by touching a proper ground device before removing the 
circuit board.  Place the circuit board where it will not be damaged. 
4.  Mount the access controller cabinet using 8-32 screws.  The access controller has four 8-
32 blind pems installed in each corner.  See page 10. 
5.  Route wiring into the cabinet.  Do not apply any power at this time.  
6.  Clean out the cabinet.  Be sure that all dirt, metal and/or wood debris is removed from the 
cabinet and that the terminal strip edge connector is clean and free of any loose particles. 
7.  Re-install the circuit board into the cabinet by gently pushing the circuit board terminals 
into the edge connector.  CAUTION - the circuit board contains static sensitive 
components.  Discharge any static electricity from your hands by touching a proper 
ground device before removing the circuit board.  
8.  Secure the circuit board to the cabinet using the screws removed in step 2. 
9.  Plug the keypad ribbon cable into the circuit board.  The cable points to the left. 
 
WARNING!  If this access control system is used to control a vehicular gate 
with an automatic gate operator, the access control device must be mounted 
a minimum of ten (10) feet away from the gate and gate operator, or in such a 
way that a person cannot operate the access control device and touch the 
gate or gate operator at the same time.
 
 
1838-065-L-3-10  
Page 
9