Intel 200 User Manual

Page of 53
 
Processor Thermal/Mechanical Information 
 
 
20  
 
Thermal and Mechanical Design Guidelines 
air, T
A
, and the local air velocity over the surface.  The higher the air velocity over 
the surface, and the cooler the air, the more efficient is the resulting cooling.  The 
nature of the airflow can also enhance heat transfer via convection.  Turbulent 
flow can provide improvement over laminar flow.  In the case of a heatsink, the 
surface exposed to the flow includes in particular the fin faces and the heatsink 
base. 
Active heatsinks typically incorporate a fan that helps manage the airflow through 
the heatsink.  
Passive heatsink solutions require in-depth knowledge of the airflow in the chassis.  
Typically, passive heatsinks see lower air speed.  These heatsinks are therefore 
typically larger (and heavier) than active heatsinks due to the increase in fin surface 
required to meet a required performance.  As the heatsink fin density (the number of 
fins in a given cross-section) increases, the resistance to the airflow increases: it is 
more likely that the air travels around the heatsink instead of through it, unless air 
bypass is carefully managed.  Using air-ducting techniques to manage bypass area 
can be an effective method for controlling airflow through the heatsink. 
2.3.1 
Heatsink Size 
The size of the heatsink is dictated by height restrictions for installation in a system 
and by the real estate available on the motherboard and other considerations for 
component height and placement in the area potentially impacted by the processor 
heatsink. The height of the heatsink must comply with the requirements and 
recommendations published for the motherboard form factor of interest. Designing a 
heatsink to the recommendations may preclude using it in system adhering strictly to 
the form factor requirements, while still in compliance with the form factor 
documentation. 
For the ATX/microATX form factor, it is recommended to use:  
•  The ATX motherboard keep-out footprint definition and height restrictions for 
enabling components, defined for the platforms designed with the micro-FCBGA of 
this design guide. 
•  The motherboard primary side height constraints defined in the ATX Specification 
V2.2 and the microATX Motherboard Interface Specification V1.2 found at 
The resulting space available above the motherboard is generally not entirely available 
for the heatsink. The target height of the heatsink must take into account airflow 
considerations (for fan performance for example) as well as other design 
considerations (air duct, etc.).