Promise Technology J610s User Manual

Page of 60
Chapter 2: Installation
25
The arrangement requires J610s or J310s units with dual I/O modules and two 
Host PCs with a SAS HBA card in each PC.
Connect the SAS HBA card in the first Host PC to the subtractive-routed port 
(CN2) on an I/O module of the first J610s or J310s unit. 
Connect the SAS HBA card in the second Host PC to the subtractive-routed port 
(CN2) on the other I/O module of the first J610s or J310s unit. 
Connect the table-routed ports (CN1) on the I/O modules of the first J610s or 
J310s unit to the subtractive-routed ports (CN2) on the I/O modules of the next 
J610s or J310s unit.
Connect the remaining J610s or J310s units in the same manner. You can mix 
J610s and J310s units in the same cascade.
Use SFF-8088 to SFF-8088 SAS cables to connect the J610s or J310s units.
Setting Up Serial Cable Connections
RS232 serial communication enables the Command Line Interface (CLI) and 
Command Line Utility (CLU) on your PC to monitor and control the VTrak. On 
VTrak, RS232 communication goes through the RJ11 serial connector on each 
controller.
 Figure 19. A serial connector is located on the I/O module. The J310s is 
shown. The J610s is similar
To set up a serial cable connection:
1.
Attach the RJ11 end of the RJ11-to-DB9 serial data cable, supplied with the 
VTrak, to the RJ11 serial connector on one of the I/O modules.
2.
Attach a null-modem cable to the DB9 end of the RJ11-to-DB9 serial data 
cable.
3.
Attach the other end of the null-modem cable to a serial port on the Host PC 
or Server.
O
I
O
I
115200
8 N 1
115200
8 N 1
115200
8 N 1
RJ11 Serial 
Connector