Promise Technology J610s User Manual

Page of 60
VTrak J610s, J310s Product Manual
40
0488
500000E01122C0F3 0x10
CN1
----
0
0519
500000E01122C493 0x10
CN1
----
0
0731
500000E01122C5B3 0x10
CN1
----
0
0751
500000E01122C5C3 0x10
CN1
----
0
0851
500000E01122C583 0x10
CN1
----
0
0864
5000155D21AB433E 0x10
CN1
----
0
0945
500000E0112313C3 0x10
CN1
----
0
The route command displays SAS addresses that are attached to one of the 
external ports on the J610s or J310s unit. Six items are reported:
Entry Number – Arbitrary numbers, listed in sequence
SAS Address – Of the disk drive or other component
Port ID – Phy numbers, shown in hexadecimal
Connector ID – One of two external SAS ports on the J610s or J310s unit
Next Entry – The next entry number for the same SAS address
Next Valid – 1 means there is another one. 0 means this is the last one
This device is connected to the J610s or J310s unit through connector CN1. See 
page 21 for a diagram of connectors on the I/O module.
If you type route at the cli> prompt and press Enter, then see the following 
message:
No SAS Routing Entry Exists
...it indicates that no devices are found on the table-routed (CN2) connector.
Uptime Command
The uptime command informs you of the elapsed period of time since the J610s 
or J310s unit was powered on.
To display uptime, at the cli> prompt, type uptime and press Enter.
cli>uptime
System has been running 1 hour 46 minutes 35 seconds