AMCC 9550SX User Manual

Page of 103
Chapter 2. CLI Syntax Reference
22
3ware Serial ATA RAID Controller CLI Guide 
Attributes
 are either Boolean Attributes or Name-Value Attributes. 
The value of a boolean attribute is deduced by presence or lack of—that 
is, the attribute is either specified, or not. For example, the command 
show alarms by default lists alarms with the most recent alarm first. If 
you include the attribute reverse, as in the command show alarms 
reverse
, alarms are listed in reverse order. 
The value of name-value attributes are expressed in the format 
attribute=value
Example:
 When adding (creating) a unit to the controller with the following 
command string, 
/c1 add type=raid1 disk=0-1
c1
 is the object, 
add
 is the command, 
type
 (for type of array) is an attribute 
with 
raid1
 as the value of the attribute, and 
disk
 is another attribute with 
0-1
 as the value (ports 0 through 1).
Information about commands is organized by the object on which the 
commands act:
Shell Object Commands. 
Shell object commands set the focus or provide 
information (such as alarms, diagnostics, rebuild schedules, and so forth) 
about all controllers in the system. For details, see “Shell Object Commands” 
on page 23. 
Controller Object Commands. 
Controller object commands provide 
information and perform actions related to a specific controller. For example, 
you use controller object commands for such tasks as seeing alarms specific 
to a controller, creating schedules during which background tasks are run, and 
setting policies for the controller. You also use the controller object command 
/cx add type to create RAID arrays. For details, see “Controller Object 
Commands” on page 29.
Unit Object Commands. 
Unit object commands provide information and 
perform actions related to a specific unit on a specific controller. For example, 
you use unit object commands for such tasks as seeing the rebuild, verify, or 
initialize status of a unit, starting, stopping, and resuming verifies, starting 
and stopping rebuilds, and setting policies for the unit. You also use the 
controller object command /cx/ux migrate to change the configuration of a 
RAID array. For details, see “Unit Object Commands” on page 59.
Port Object Commands. 
Port object commands provide information and 
perform actions related to a drive on a specific port. For example, you use port 
object commands for such tasks as seeing the status, model, or serial number 
of the drive. For details, see “Port Object Commands” on page 77
BBU Object Commands. 
BBU object commands provide information and 
perform actions related to a Battery Backup Unit on a specific controller. For 
details, see “BBU Object Commands” on page 82.