AMCC 9500S User Manual

Page of 103
Chapter 2. CLI Syntax Reference
38
3ware Serial ATA RAID Controller CLI Guide 
/c
x
 show allunitstatus
This command presents a count of total and Not Optimal units managed by 
the specified controller /cx. For more about the meaning of Not Optimal, see 
“Shell Object Commands” on page 23. 
Example:
 //localhost> /c0 show allunitstatus
 /c0 Total Optimal Units = 2
 /c0 Not Optimal Units = 0
/c
x
 show drivestatus
This command reports a list of drives and their port assignment, status, the 
unit with which they are associated, their size in gigabytes and blocks, and the 
serial number assigned by the drive manufacturer. (Definitions of the drive 
statuses are available in the 3ware Serial ATA RAID Controller User Guide.)
Example:
 //localhost> /c0 show drivestatus
 Port   Status           Unit   Size        Blocks        Serial
 --------------------------------------------------------------
 p0     OK               u0     149.05 GB   312581808     3JS0TF14
 p1     OK               u0     149.05 GB   312581808     3JS0TETZ
 p2     OK               u1     149.05 GB   312581808     3JS0VG85
 p3     OK               u1     149.05 GB   312581808     3JS0VGCY
 p4     OK               u1     149.05 GB   312581808     3JS0VGGQ
 p5     OK               u2     149.05 GB   312581808     3JS0VH1P
 p6     OK               -      149.05 GB   312581808     3JS0TF0P
 p7     OK               -      149.05 GB   312581808     3JS0VF43
 p8     OK               -      149.05 GB   312581808     3JS0VG8D
 p9     NOT-PRESENT      -      -           -             -
 p10    NOT-PRESENT      -      -           -             -
 p11    NOT-PRESENT      -      -           -             -