 show
This command shows summary information about the specified unit /cx/ux. If 
the unit consists of sub-units as with the case of RAID-1, RAID-5, RAID-10, 
RAID-50, then each sub-unit is further presented. If the Auto-Carving policy 
was on at the time the unit was created and the unit is over the carve size, 
multiple volumes were created and are displayed at the end of the summary 
information. Similarly, if the unit was created using the 3ware BIOS utility 
3BM and a size was entered in the Boot Volume Size field, multiple volumes 
were created and will be displayed. (Note that a volume created using the 
Boot Volume Size feature does not have to be used as a boot volume.)
One application of the /cx/ux show command is to see which sub-unit of a 
degraded unit has caused the unit to degrade and which disk within that sub-
unit is the source of degradation. Another application is to see the source and 
destination units during a migration.
Example:
//localhost> /c0/u0 show
 Unit     UnitType  Status         %RCmpl  %V/I/M  Port  Stripe  Size(GB)
 ------------------------------------------------------------------------
 u0       RAID-50   OK             -       -       -     64K     596.05    
 u0-0     RAID-5    OK             -       -       -     64K     -         
 u0-0-0   DISK      OK             -       -       p0    -       149.10    
 u0-0-1   DISK      OK             -       -       p2    -       149.10    
 u0-0-2   DISK      OK             -       -       p3    -       149.10    
 u0-1     RAID-5    OK             -       -       -     64K     -         
 u0-1-0   DISK      OK             -       -       p4    -       149.10    
 u0-1-1   DISK      OK             -       -       p5    -       149.10    
 u0-1-2   DISK      OK             -       -       p6    -       149.10
 //localhost> /c0/u1 show
 Unit     UnitType  Status         %RCmpl  %V/I/M  Port  Stripe  Size(GB)
 ------------------------------------------------------------------------
 u1       RAID-0    OK             -       -       -     64K     3576.06   
 u1-0     DISK      OK             -       -       p0    -       298.01    
 u1-1     DISK      OK             -       -       p1    -       298.01    
 u1-2     DISK      OK             -       -       p2    -       298.01   
 u1-3     DISK      OK             -       -       p3    -       298.01    
 u1-4     DISK      OK             -       -       p4    -       298.01    
 u1-5     DISK      OK             -       -       p5    -       298.01    
 u1-6     DISK      OK             -       -       p6    -       298.01    
 u1-7     DISK      OK             -       -       p7    -       298.01 
 u1-8     DISK      OK             -       -       p8    -       298.01  
 u1-9     DISK      OK             -       -       p9    -       298.01  
 u1-10    DISK      OK             -       -       p10   -       298.01   
 u1-11    DISK      OK             -       -       p11   -       298.01    
 u1/v0    Volume    -              -       -       -     -       2047.00   
 u1/v1    Volume    -              -       -       -     -       1529.06