Chapter 2. CLI Syntax Reference
76
3ware Serial ATA RAID Controller CLI Guide 
Example of migrate output
The following is an example of how migrating units will be displayed. In this 
example, the report indicates that 
/c0/u3 
is a migrating unit with 39% 
completion. The report also indicate that Source Unit 
su0 
is of type RAID-1 
and Destination Unit 
du0
 is of type RAID-10.
3ware CLI> /c0 show
 Unit  UnitType  Status       %RCmpl  %V/I/M  Stripe  Size(GB)  Cache  AVrfy
 ---------------------------------------------------------------------------
 u0    RAID-5    OK            -       -       64K     596.004   ON     OFF
 u2    SPARE     OK            -       -       -       149.042   -      OFF
 u3    Migrator  MIGRATING     -       39      -       149.001   ON     OFF
 Port   Status           Unit   Size        Blocks        Serial
 ---------------------------------------------------------------
 p0     OK               u0     149.05 GB   312581808     WD-WCANM1771318
 p1     OK               u0     149.05 GB   312581808     WD-WCANM1757592
 p2     OK               u0     149.05 GB   312581808     WD-WCANM1782201
 p3     OK               u0     149.05 GB   312581808     WD-WCANM1753998
 p4     OK               u2     149.05 GB   312581808     WD-WCANM1766952
 p5     OK               u3     149.05 GB   312581808     WD-WCANM1882472
 p6     OK               u0     149.05 GB   312581808     WD-WCANM1883862
 p7     OK               u3     149.05 GB   312581808     WD-WCANM1778008
 p8     OK               -      149.05 GB   312581808     WD-WCANM1770998
 p9     NOT-PRESENT      -      -           -             -
 p10    OK               u3     149.05 GB   312581808     WD-WCANM1869003
 p11    OK               u3     149.05 GB   312581808     WD-WCANM1762464
 3ware CLI> /c0/u0 show
 Unit     UnitType  Status         %RCmpl  %V/I/M  Port  Stripe  Size(GB)
 ------------------------------------------------------------------------
 u3       Migrator  MIGRATING      -       39      -     -       -
 su3      RAID-1    OK             -       -       -     -       149.001
 su3-0    DISK      OK             -       -       p5    -       149.001
 su3-1    DISK      OK             -       -       p7    -       149.001
 su3/v0   Volume    -              -       -       -     -       149.001
 du3      RAID-10   OK             -       -       -     16K     298.002
 du3-0    RAID-1    OK             -       -       -     -       -
 du3-0-0  DISK      OK             -       -       p5    -       149.001
 du3-0-1  DISK      OK             -       -       p7    -       149.001
 du3-1    RAID-1    OK             -       -       -     -       -
 du3-1-0  DISK      OK             -       -       p10   -       149.001
 du3-1-1  DISK      OK             -       -       p11   -       149.001
 du3/v0   Volume    -              -       -       -     -       149.001