AMCC 9500S User Manual

Page of 103
BBU Object Commands
www.3ware.com 
85
/c
x
/bbu show serial
This command 
shows
 the BBU serial number. 
/c
x
/bbu show fw
This command 
shows
 the BBU firmware version number. 
/c
x
/bbu show pcb
This command 
shows
 the PCB revision number on the BBU. 
/c
x
/bbu show bootloader
This command 
shows
 the BBU's boot loader version.
/c
x
/bbu show all
This command shows the current settings of all BBU-related attributes: ready, 
status, batinst, lasttest, volt, temp, cap, serial, fw, pcb, bootloader. 
Example:
 //localhost> /c1/bbu show all
/c1/bbu Firmware Version          = BBU: 1.04.00.007
 /c1/bbu Serial Number             = Engineering Sample.
 /c1/bbu BBU Ready                 = Yes
 /c1/bbu BBU Status                = OK
 /c1/bbu Battery Voltage           = OK
 /c1/bbu Battery Temperature       = OK
 /c1/bbu Estimated Backup Capacity = 241 Hours
 /c1/bbu Last Capacity Test        = 22-Jun-2004
 /c1/bbu Battery Installation Date = 20-Jun-2004
 /c1/bbu Bootloader Version        = BBU 0.02.00.002
 /c1/bbu PCB Revision              = 65
//localhost>