Black Box LPJ016A-F User Manual

Page of 43
724-746-5500   |   blackbox.com 
Page 38
724-746-5500   |   blackbox.com 
802.3af and 802.3at PoE Gigabit Injectors
Table B-1 (Continued). SNMP MIB.
  OID 
Name 
Type 
Value 
Description
  2.3.6.1.24852.2.2.14.0 
poeSystemControlDCPower*** 
INTEGER 
Read-write 
 Sets the value of available 
power in watts to be sup-
plied by secondary (DC) 
power source.
  2.3.6.1.24852.2.2.15.0 
poeSystemControlBothPower*** 
INTEGER 
Read-write 
 Sets the value of the total 
available power in watts 
to be supplied by both 
power sources.
  2.3.6.1.24852.2.3.1.1.1~24  poePortIndex 
INTEGER 
Read-only 
 A unique value for each 
port.
  2.3.6.1.24852.2.3.1.2.1~24  poePortPowerEnable 
INTEGER 
Disable (1) 
Setting this object at a 
 
     
 
(1.2147483647)   Enable (2) 
 value enable (2) enables 
the detection mechanism 
for this port.
     
 
 
 
 Setting this object at a 
value disable (1) disables 
the detecton mechanism 
for this port.
  2.3.6.1.24852.2.3.1.3.1~24  poePortControlMaxPower*** 
INTEGER 
Read-write 
 This command specifies 
the maximum power in 
[watts] to the port.
  2.3.6.1.4.1.24852.2.3.1.4.0  poePortCurrentStatus*** 
INTEGER 
undercurrent(1)  Describes a current port 
     
 
 
overCurrent(2)  status related to the 
     
 
 
both(3) 
power generation. The 
     
 
 
ok(4) 
 value undercurrent(1) 
indicates that the port 
current is below the mini-
mal value since the attri-
bute was last cleared.
     
 
 
 
 The value overCurrent(2) 
indicates that the port 
current exceeds the maxi-
mum value since the attri-
bute was last cleared. The 
value both(3) indicates 
that both undercurrent 
and overCurrent were 
detected since the attri-
bute was last cleared. The 
value ok(4) indicates nei-
ther an undercurrent or 
an overcurrent condition 
has been detected since 
the attribute was last 
cleared.