I N T E R F AC E   M O D E L   9 8 4 0   V E R   6 . 0 . 2  
INTRODUCTION 
The Model 9840 is a CE compliant and versatile precision instrument intended for the 
digital readout of strain gage sensors such as load cells and torque cells.  Optical 
encoders are also supported. 
 
Here is a quick listing of its features: 
 
• Full 
bi-polar 
6 digit display (
±999,999) using two line, 20 character, vacuum 
fluorescent display for clear, precise indication of measured quantities and limit status. 
 
•  No knobs or dials.  No internal jumpers.  All adjustment and calibration is done using 
user-friendly front panel menus.  Keylock option to prevent accidental or unauthorized 
changes to the unit’s setup. 
 
• Measure 
load and gross weight in pounds, kilograms, Newtons, PSI, MegaPascals, 
kilo-pounds, kilo-Newtons, metric tons, mV/V, or grams.  User defined base area for 
PSI and MPa.  Tare at any time.  The sum of the loads on both channels is also 
availabe. 
 
• Measure 
torque and gross torque in Pound-Inches, Newton-Meters, Ounce-Inches, 
or mV/V. Tare at any time.  The sum of the torques on both channels is also availabe. 
 
•  Capture the load peak and valley, display in pounds, kilograms, Newtons, PSI, 
MegaPascals, kilo-pounds, kilo-Newtons, metric tons, mV/V, or grams.  Reset at any 
time. 
 
•  Capture the torque peak and valley, display in in Pound-Inches, Newton-Meters, 
Ounce-Inches, or mV/V.  Reset at any time. 
 
• Measure 
position and velocity with optional encoder input.  Display in English units, 
metric units, or in percent of a user defined base length.  Reset at any time. 
 
•  Four contact closure Limit switches.  You can set which signal drives the limit (load, 
torque, peak, valley, position, or velocity), normally open / normally closed, set point, 
and manual reset (latched) or automatic reset (not latched). 
 
•  Print current readings of load, torque, peak, valley, position, and velocity using the 
currently selected units at the touch of one button (optional). 
 
•  Automatic identification of calibrated cells with auto-id option. 
 
•  Calibration for cells using manufacturer’s milli-volt per volt calibration factor, 6 point 
mass and milli-volt per volt, 2 or 5 point known mass, 6 point torque and milli-volt per 
volt, 2 or 5 point known torque, or internal precision shunt calibration.  A back panel 
switch allows you to choose between two values used for the shunt calibration so 
there is no need to open the unit. 
 
•  Analog output of any signal (load, torque, peak, valley, position, velocity) with user 
defined scale factor and offset.  Large, buffered 
± 10.00 volt output. 
M O D E L   9 8 4 0                                                                                                                                                          P G   4  
P U B .
 
2 8 5 6 - 1 6