3.2.2.6  Clear Interrupt 
 
Reading from 1Ch will clear the add-on interrupt.  
 
3.2.2.7  The Analog Input Selection Register 
 
The analog input channel selection register uses address 10h and 
address 14h is used by the analog gain control selection register. Write 0-31 to 
port 10h to select the channel number (for differential input, write 0-15). 
Write 0-3 to port 14h to select the gain control. 
 
 
 
 
 
 
 
 
 
     Figure 3-2. Analog input control. 
 
Note:  
1.   For single ended inputs, channels 0-31 are available. For 
differential inputs, channels 0-15 are available.  If you enter a 
channel number greater than the number available, those channels 
will be ignored.  Thus, for single-ended inputs, only the last 5 bits 
are taken as the channel number. And for differential inputs, only 
the last 4 bits are taken as the channel number. 
 
2.   Only the last two digits are used as the gain control code. The gain 
control codes and corresponding gains are shown below : 
 
           For OME-PCI-1002L: 
Gain code
[0 0] 
[0 1] 
[1 0] 
[1 1] 
Gain 1 
4  8 
 
Analog inputs 
… 
Channel select 
Analog 
Mux. 
Select
 
Gain control 
ADC 
AMP 