Omega 1002 User Manual

Page of 48
 
6.  Diagnostic Program 
 
6.1  Power-ON Plug & Play Test 
 
Below are the steps for the power-on Plug & Play test: 
Step 1: Power-off the PC 
Step 2: Install OME-PCI-1002 without any extra external connections 
Step 3: Power-on the PC and watch the PC screen very carefully 
Step 4: The PC will perform its self-test first 
Step 5: The PC will detect the non-PCI physical devices installed in the system 
Step 6: The PC will display the information for these devices 
Step 7: The PC will detect the PCI Plug & Play devices installed in the system 
All PCI-device information will be shown Æ pay careful attention 
Æ There will be a PCI device with vendor_ID=1234, device_ID=1002 (OME-PCI-
1002) 
 
      If the Plug & Play ROM-BIOS successfully detects the OME-PCI-1002 card during 
the power-on state, the DOS and Windows software driver will also be able to detect the 
card. If the Plug & Play ROM-BIOS can not find the OME-PCI-1002, the software driver 
will not function. Therefore the user must make sure that the power-on detection is 
correct. 
 
 
 
 
6.2  Driver Plug & Play Test 
 
Step 1: Power-off the PC. 
Step 2: Install OME-PCI-1002 without any extra external connector. 
Step 3: Power-on PC and run DEMO7.EXE. 
Step 4: The I/O base address of all OME-PCI-1002 cards installed in the system will be 
displayed. 
Step 5: Verify that the total number of boards is correct 
Step 6: If more than one card, install a 20-pin flat cable on one of the OME-PCI-1002 
45