NEC 2000 IVS User Manual

Page of 156
ND-45504 (E)
CHAPTER 3
Addendum-002
Page 11
OCTOBER, 1998
Revision 2.2
2. INSTALLATION CONDITIONS FOR CONTROL CIRCUIT CARDS
2.1 PN-CP00/PN-CP00-B/PN-CP00-C (MP)
Mount the PN-CP00/PN-CP00-B/PN-CP00-C in the MP slot of PIM0.
2.2 PN-CP01 (FP)
1.
The PN-CP01 is required only if any of the following is true.
More than one PIM is used.
A PN-2DLCC is used.
A PN-AP01 is used.
OAI, ACD, No. 7 CCIS or ISDN is used.
2.
When the system is equipped with two PIMs, mount one PN-CP01 in the FP slot of PIM0. When the sys-
tem is equipped with more than two PIMs--depending on the number of additional PIMs used--mount one
PN-CP01 in the FP slot of PIM0 and one PN-CP01 in the MP/FP slot of PIM2, PIM4 and PIM6.
Figure 3-2   MP/FP Card Mounting Slots
PIM3
PIM7
PIM2
PIM6
F
P
F
P
PIM1
PIM5
PIM0
PIM4
F
P
M
P
F
P