Electrical specifications
1005
Electrical specifications
Power requirements
shows
the power requirements for the NTCK16AX and NTCK16BX generic Central
Office trunk cards.
Table 421
NTCK16 circuit card power requirements
Voltage
Idle Current
Active current
+15.0 V dc
(See
170 ma
330 ma
-15.0 V dc
(See
170 ma
249 ma
+8.5 V dc
(See
101 ma
100 ma
+5.0 V dc
160 ma
322 ma
Note 1: Analog circuitry is powered with +/-12 V generated from +/-15
V. The maximum current imbalance between the +/-15 V rails is 100
ma per circuit pack.
Note 2: 8.5V is regulated to give 5 V.
Environmental specifications
lists the environmental specifications of the NTCK16AX and
NTCK16BX generic Central Office trunk cards.
Table 422
NTCK16 circuit card environmental specifications
Parameter
Specifications
Operating temperature
10 to 45 degrees C
Operating humidity
20 to 80% RH (non-condensing)
Storage temperature
–20 to +60 degrees C
Storage humidity
5 to 95% Relative Humidity
Pad switching
The NTCK16AX and NTCK16BX generic Central Office trunk cards support
the North American loss plan. Software configuration allows the selection of
4 dB loss pads on a per unit basis.