Nortel Networks 311 User Manual

Page of 1134
1072
NTRB21 DTI/PRI/DCH TMDI card
combinations each for Mu255 to Mu255, Mu255 to A-Law, A-Law to Mu255,
and A-Law to A-Law. These values are selected to meet the EIA loss and
level plan.
Table 437
Digital pad values and offset allocations
Offset
PAD set 0
PAD set 1
0
0dB
–7db
1
2dB
–8db
2
3dB
–9db
3
4dB
–10db
4
5dB
0.6db
5
6.1dB
7db
6
8dB
9db
7
–1dB
10db
8
–3dB
11db
9
–4dB
12db
A
idle code, 7F
3db
B
unassigned code, FF
14db
C
1dB
spare
D
–2dB
spare
E
–5db
spare
F
–6db
spare
D-channel interface
The D-channel interface is a 64 kbps, full-duplex, serial bit-stream
configured as a Data Circuit-terminating Equipment (DCE) device. The
data signals include:
receive data output
transmit data input
receive clock output
transmit clock output
The bit rate of the receive and transmit clocks can vary slightly from each
other. This is determined by the transmit and receive carrier clocks.
Feature selection through software configuration for the D-channel includes:
56 kbps
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008
Copyright © 2003-2008, Nortel Networks
.