Nortel Networks 311 User Manual

Page of 1134
116
Option settings
Table 58
QPC775 vintage E switch settings
SW1
SW2
SW4
System
1
2
3
4
1
2
3
4
1
2
3
4
CS 1000M SG
on
on
on
on
off
off
off
off
off
on
*
*
CS 1000M MG
on
off
off
off
off
off
off
off
**
on
*
*
*Cable length between the J3
faceplate connectors:
0–4.3 m (0–14 ft)
off
off
4.6–6.1 m (15–20 ft)
off
on
6.4–10.1 m (21–33 ft)
on
off
10.4–15.2 m (34–50 ft)
on
on
*If there is only one Clock Controller card in the system, set to OFF. If there are two Clock Controller
cards, determine the total cable length between the J3 connectors (no single cable can exceed 25
ft.) and set these two switch positions for this cable length, as shown above. The maximum total
(combined) length is 50 ft. Set the switches on both cards to the same settings.
**Set to ON for clock controller 0. Set to OFF for clock controller 1.
QPC841 4-Port Serial Data Interface card
through
list option settings for
the QPC841 4-Port SDI card.
Table 59
QPC841 port 1 and 2 address selection
Device number
SW14
Port 1
Port 2
1
2
3
4
5
6
7
8
0
1
off
off
off
off
off
on
on
on
2
3
off
off
off
off
off
on
on
off
4
5
off
off
off
off
off
on
off
on
6
7
off
off
off
off
off
on
off
off
8
9
off
off
off
off
off
off
on
on
10
11
off
off
off
off
off
off
on
off
Note 1: On SW16, positions 1, 2, 3, and 4 must be OFF.
Note 2: To avoid address conflicts, SW14 and SW15 can never show identical settings.
Note 3: To disable ports 1 and 2, set SW14 position 1 to ON.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008
Copyright © 2003-2008, Nortel Networks
.