Nortel Networks 311 User Manual

Page of 1134
Installation and configuration
197
MMI Master or Slave
This setting is used only if daisy-chaining the cards to the MMI terminal or
modem. This setting determines whether this card is a master or a slave in
the MMI daisy-chain. Select the master setting if this card is the card that is
cabled directly into the MMI terminal or modem; select the slave setting if
this card is cabled to another Lineside T1 card in a daisy chain.
describe the proper dip
switch settings for each type of T1 link. After the card has been installed, the
MMI displays the DIP switch settings the command Display Configuration
is used. See
for details on how to
invoke this command.
Table 91
Lineside T1 card-T1 Switch 1 (S1) dip switch settings
Dip Switch
Number
Characteristic
Selection
1
MMI port speed selection
On = 1200 baud
Off = 2400 baud
2
T1 signaling
On = Ground start
Off = Loop start
3–6
XPEC Address for the Lineside T1 card
See
7
Not Used
Leave Off
8
Reserved for SL-100 use
Leave Off
Table 92
Lineside T1 card - XPEC address dip switch settings (Switch S1, positions 3 - 6)
XPEC
Address
S1 Switch
Position 3
S1 Switch
Position 4
S1 Switch
Position 5
S1 Switch
Position 6
00
Off
Off
Off
Off
01
Off
Off
Off
On
02
Off
Off
On
Off
03
Off
Off
On
On
04
Off
On
Off
Off
05
Off
On
Off
On
06
Off
On
On
Off
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008
Copyright © 2003-2008, Nortel Networks
.