Overview
Figure 1
IPE line cards shown installed in an NT8D37 IPE module
When installing line cards, follow these general procedures:
Step
Action
1
Configure the jumpers and switches on the line card (if any) to meet
system needs.
2
Install the line card into the selected slot.
3
Install the cable that connects the backplane connector on the IPE
module to the module I/O panel.
4
Connect a 25-pair cable from the module I/O panel connector to the
Main Distribution Frame (MDF).
5
Connect the line card output to the selected terminal equipment
at the MDF.
6
Configure the individual line interface unit using the Analog
(500/2500-type) Telephone Administration program LD 10 for analog
line interface units and Multi-line Telephone Administration program
LD 11 for digital line interface units.
—End—