Nortel Networks 311 User Manual

Page of 1134
Installation and configuration
221
equipment through the switch software, the T1 channel number must be
cross-referenced to the corresponding card unit number. This mapping is
shown in
Table 102
DX-30 to T1 time slot mapping
TN
T1 Channel Number
Motherboard
0
1
Motherboard
1
2
Motherboard
2
3
Motherboard
3
4
Motherboard
4
5
Motherboard
5
6
Motherboard
6
7
Motherboard
7
8
Motherboard
8
9
Motherboard
9
10
Motherboard
10
11
Motherboard
11
12
Motherboard
12
13
Motherboard
13
14
Motherboard
14
15
Motherboard
15
16
Daughterboard
0
17
Daughterboard
1
18
Daughterboard
2
19
Daughterboard
3
20
Daughterboard
4
21
Daughterboard
5
22
Daughterboard
6
23
Daughterboard
7
24
Disconnect supervision
The Lineside T1 card supports far-end disconnect supervision by opening
the tip side toward the terminal equipment upon the system’s detecting a
disconnect signal from the far-end on an established call. The Supervised
Analog Line feature (SAL) must be configured in LD 10 for each Lineside T1
port. At the prompt FTR, respond:
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008
Copyright © 2003-2008, Nortel Networks
.