Nortel Networks 311 User Manual

Page of 1134
312
NT5D33 and NT5D34 Lineside E1 Interface cards
terminate at the end of the time period or when a
Stop Test
command
is issued. Only
Stop Test
stops a test with a duration selection of 99;
however, the
STOP
command terminates a test set to any duration from one
to 99. After entering the test number, a prompt similar to
appears.
Figure 77
Test parameters screen
Before a test is run, be sure to verify that the card is disabled, as the tests
interfere with calls currently in process.
During a test, if an invalid word is received, this is recorded by a failure
peg counter. The peg counter has a limit of 65,000. At the end of the test,
the Test Results message indicates how many failures, if any, occurred
during the test.
shows which test to run for the associated
equipment.
Table 127
MMI Tests
Test number
Equipment Tested
Test Description
1
LEI
Local loopback
2
E1 link, LEI, and E1
network
External loopback
3
CPE device and E1
network
Network loopback
Test 1, local loopback, loops the E1 link signaling toward itself at the
backplane connector. Test data is generated and received on all timeslots.
If this test fails, it indicates that the LEI is defective.
illustrates how the signaling is looped back
toward itself.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008
Copyright © 2003-2008, Nortel Networks
.