Table 165
XMFC sender specifications
Forward frequencies in DOD mode:
1380, 1500, 1620, 1740, 1860, 1980 Hz
Backward frequencies in DOD mode:
1140, 1020, 900, 780, 660, 540 Hz
Frequency tolerance:
+/- 0.5 Hz from nominal
Power level at each frequency:
Selectable: 1 of 16 levels
Level difference between frequencies:
< 0.5 dB
Harmonic Distortion and Intermodulation
37 dB below level of 1 signaling frequency
Time interval between start of 2 tones:
125 usec.
Time interval between stop of 2 tones:
125 usec.
Table 166
XMFC receiver specifications
Input sensitivity:
accepted:
rejected:
-5 to -31.5 dBmONew CCITT spec.
-38.5 dBmOBlue Book
Bandwidth twist:
accepted:
rejected:
fc +/- 10 Hz
fc +/- 60 Hz
Amplitude twist:
accepted:
difference of 5 dB between adjacent frequencies
difference of 7 dB between non-adjacent frequencies
Norwegian requirement
rejected:
difference of 12 dB (for unloaded CO trunks)
difference of 20 dB between any two frequencies
Operating time:
< 32 msec.
Release time:
< 32 msec.
Tone Interrupt no release:
< 8 msec. Receiver on, while tone missing
Longest Input tone ignored:
< 8 msec. Combination of valid frequencies
Noise rejection:
S/N > 18 dB No degradation, in band white noise
S/N > 13 dB Out-of-band disturbances for CCITT
XMFE sender and receiver specifications
and
provide the operating
requirements for the XMFC/MFE card when it is configured as an XMFE
card. These requirements conform to French Socotel specifications
ST/PAA/CLC/CER/692.