Nortel Networks 311 User Manual

Page of 1134
524
NT8D02 and NTDK16 Digital Line cards
Table 202
Digital line card - environmental specifications
Parameter
Specifications
Operating temperature
0

to +60

C (+32 to +140

F), ambient
Operating humidity
5 to 95% RH (non-condensing)
Storage temperature
–40

to +70

C (–40

to +158

F)
shows
the environmental specifications of the card.
Table 203
Digital line card - environmental specifications
Parameter
Specifications
Operating temperature
0

to +60

C (+32 to +140

F), ambient
Operating humidity
5 to 95% RH (non-condensing)
Storage temperature
–40

to +70

C (–40

to +158

F)
shows
the environmental specifications of the NT8D02 Digital Line Card.
Table 204
NT8D02 Digital Line Card - environmental specifications
Parameter
Specifications
Operating temperature
0

to +60

C (+32 to +140

F), ambient
Operating humidity
5 to 95% RH (non-condensing)
Storage temperature
–40

to +70

C (–40

to +158

F)
Connector pin assignments
shows
the I/O pin designations at the backplane connector, which is arranged as
an 80-row by 2-column array of pins. Normally, these pin positions are
cabled to 50-pin connectors at the I/O panel in the rear of each module for
connection with 25-pair cables to the MDF.
The information in
is provided as a reference and diagnostic aid at the
backplane, since the cabling arrangement can vary at the I/O panel. See
Communication Server 1000M and Meridian 1 Large System Installation and
Configuration 
(NN43021-310) for cable pinout information for the I/O panel.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008
Copyright © 2003-2008, Nortel Networks
.