Electrical specifications
677
Table 233
Universal trunk card - trunk interface electrical characteristics
Trunk Types
Characteristic
CO / FX / WATS
DID / TIE
RAN
Paging
Terminal impedance
600 or 900 ohms
(Note 1)
600 or 900 ohms
(Note 1)
600/900 ohms
(Note 1)
600 ohms
Balance impedance
600 or 900 ohms
(Note 1), 3COM, or
3CM2 (Note 2)
600 or 900 ohms
(Note 1), 3COM,
or 3CM2 (Note 2)
N/A
N/A
Supervision type
Ground or loop
start (Note 3)
Loop start (with
ans sup) (Note 3)
Continuous,
level, or pulse
N/A
DC signaling loop
length (max)
1700-ohm loop with
near-end battery of
–42.75 V
2450-ohm loop
with near-end
battery of –44 V
600/900-ohm
loop
600 ohm
loop
Far-end battery
–42 to –52.5 V
(Note 4)
–42 to –52.5 V
–42 to –52 V
N/A
Minimum detected
loop current
20 mA
10 mA
10 mA
N/A
Ground potential
difference
±3 V
±3 V
±1 V
±1 V
Low DC loop
resistance during
outpulsing
<300 ohms
N/A
N/A
N/A
High DC loop
resistance
Ground start
ˇ
S 30k ohms;
loop start
ˇ
S 5M ohms
N/A ˇ
S
N/A
N/A
Ring detection
17 to 33 Hz 40 to
120 V rms
N/A
N/A
N/A
Note 1: Selected in software.
Note 2: Selected by jumper strap settings on card. Refer to
,
and
for details.
Note 3: For loop extender application, the maximum voltage applied between tip and ring is –105 V
±5%. The minimum dc loop resistance for this type of application is 1800 ohms.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008