Nortel Networks 311 User Manual

Page of 1134
Electrical specifications
681
Characteristic
DID trunk
CO trunk
Signaling type
Loop start
Ground or loop start
Far end battery
- 42 to - 52.5 V
- 42 to - 52.5 V
Near end battery
N/A
- 42.75 to - 52.5 V
Minimum loop current
N/A
20 mA
Ground potential difference
+ 3 V
+ 3 V
Low DC loop resistance
during outpulsing
N/A
< 300 ohms
High DC loop resistance
N/A
Ground start equal to or greater
than 30 kohms; loop start equal
to or greater than 5 Mohms
Line leakage
Equal to or greater than 30 kohms
(tip to ring, tip to ground, ring to
ground)
Equal to or greater than 30 kohms
(tip to ring, tip to ground, ring to
ground)
Effective loss
See
Power requirements
Power to the NT8D14 Universal Trunk card is provided by the module power
supply (ac or dc).
Table 237
Power requirements for universal trunk card
Voltage
Tolerance
Current (max.)
+15.0 V dc
±5%
306 mA
–15.0 V dc
±5%
306 mA
+5.0 V dc
±5%
750 mA
+8.5 V dc
±2%
450 mA
–48.0 V dc
±5%
415 mA
Power to the universal trunk card is provided by the module power supply
(ac or dc).
lists the power
requirements for the universal trunk card.
Table 238
Power requirements
Voltage
Tolerance
Current (max.)
+15.0 V dc
±5%
306 mA
–15.0 V dc
±5%
306 mA
+5.0 V dc
±5%
750 mA
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008
Copyright © 2003-2008, Nortel Networks
.