Nortel Networks 311 User Manual

Page of 1134
Electrical specifications
775
Table 291
Power requirements
Voltage
Tolerance
Max current
+15.0 V dc
±5%
200 mA
–15.0 V dc
±5%
200 mA
+8.5 V dc
±2%
200 mA
–48.0 V dc
±5 %
415 mA
Power requirements for the NT8D15 E and M Trunk Card are specified in
.
Table 292
Power requirements
Voltage
Tolerance
Idle
Current
Active
Current
+/- 15.0 V DC
+/- 5%
200mA
200 mA
+ 8.5 V DC
+/- 2%
200 mA
200 mA
- 48.0 V DC
+/- 5%
415 mA
415 mA
+5.0 V DC
N/A
N/A
N/A
Environmental specifications
provides the
environmental specifications for the E and M Trunk card.
Table 293
Environmental specifications
Parameter
Specifications
Operating temperature
0 to +60 degrees C
(32 to +140 degrees F), ambient
Operating humidity
5 to 95% RH (non-condensing)
Storage temperature
–40 to +70 degrees C
(–40 to +158 degrees F)
provides the
environmental specifications for the E and M Trunk card.
Table 294
Environmental specifications
Parameter
Specifications
Operating temperature
0 to +60 degrees C
(32 to +140 degrees F), ambient
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008