NT8D41AA Serial Data Interface Paddle Board
Table 317
SDI paddle board baud rate switch settings
Port 1 – SW2
Port 2 – SW3
Baud
rate
1
2
3
4
1
2
3
4
150
off
off
on
on
off
off
on
on
300
off
on
off
on
off
on
off
on
600
off
off
off
on
off
off
off
on
1200
off
on
on
off
off
on
on
off
2400
off
off
on
off
off
off
on
off
4800
off
on
off
off
off
on
off
off
9600
off
off
off
off
off
off
off
off
DTE/DCE/Fiber mode
Each serial port can be configured to connect to a terminal (DTE
equipment), a modem (DCE equipment), or a Fiber Superloop Network card.
Instructions for setting the switches SW5, SW6, SW7, and SW8 are shown
in
Table 318
NT8D41AA DTE/DCE/Fiber switch settings
Port 1 – SW5
Port 1 – SW6
Mode
1
2
3
4
5
6
1
2
3
4
5
6
DTE (terminal)
on
on
on
on
on
on
off
off
off
off
off
off
DCE (modem)
off
off
off
off
off
off
on
on
on
on
on
on
NT1P61 (Fiber)
on
on
on
on
on
off
off
off
on
on
on
on
Port 2 – SW7
Port 2 – SW8
DTE (terminal)
on
on
on
on
on
on
off
off
off
off
off
off
DCE (modem)
off
off
off
off
off
off
on
on
on
on
on
on
NT1P61 (Fiber)
on
on
on
on
off
off
off
off
on
on
on
on
Software service changes
Once the NT8D41 SDI paddle board has been installed in the system,
the system software needs to be configured to recognize it. This is done
using the Configuration Record program LD 17. Instructions for running
the Configuration Record program are found in Software Input/Output
Reference — Administration 
(NN43001-611).