Nortel Networks 311 User Manual

Page of 1134
90
Option settings
Table 21
NT6D42 recommended options for North American and British Telecom
Application
Ringing
frequency
Ringing
voltage
Jumper locations
Ringing output
North America
20 Hz
86 V ac
P5
High voltage
message waiting
Low impedance
British Telecom
25 Hz
80 V ac
P4
No high voltage
message waiting
Low impedance
Table 22
NT6D42 jumper locations P4 and P5
High voltage message waiting
Pin location
Disable
Jumper in P4
Enable
Jumper in P5
Note: One jumper must be installed.
Table 23
NT6D42 jumper location J7
Ringing output
Jumper location J7
Low impedance (normal)
Connect pins 1 and 2
High impedance (Australia)
Connect pins 2 and 3
Table 24
NT6D42 SW1
Ringing frequency (Hz)
Position SW1
20
1
25
2
50
3
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008
Copyright © 2003-2008, Nortel Networks
.