Omega OMB-DAQBOARD-3000 User Manual

Page of 108
 
Using Multiple Inputs to Control One DAC Output 
Update Mode: Rising Edge, for each of 2 channels 
Criteria Used:  Inside Window, for each of 2 channels
 
 
 
The figure below shows how multiple inputs can update one output.  In the following figure the DAC2 
analog output is being updated.  Analog input Channel 3 has an inside-the-window setpoint applied.  
Whenever Channel 3’s input goes inside the programmed window, DAC2 will be updated with 3.0V.   
 
Analog input Channel 7 also has an inside-the-window setpoint applied.  Whenever Channel 7’s input goes 
inside the programmed window, DAC2 will be updated with minus 7.0V.   
 
Limit A 
(for Ch3) 
 
Limit B 
(for Ch3) 
 
 
 
 
 
 
 
Limit A 
(for Ch7) 
 
Limit B 
(for Ch7) 
 
 
 
 
Detection (Ch3) 
 
 
Detection (Ch7) 
 
 
 
+3.0 V 
 
DAC2  0.0 V 
 
 
-7.0 V 
 
 
Using Two Criteria to Control an Output* 
 
 
  
 
 
 The update on True Only mode was selected and therefore the updates for DAC2 will only occur when the criteria is 
met.  However, in the above figure we see that there are 2 setpoints acting on one DAC.  We can also see that the two 
criteria can be met simultaneously.  When both criteria are True at the same time, the DAC2 voltage will be associated 
with the criteria that has been most recently met. 
6-10   Setpoint Configuration for Output Control 
908794 
DaqBoard/3000 Series User’s Manual