7-8    Specifications  
988093
 
Note: Specifications are subject to change without notice. 
 
 
PDQ30 Type T Thermocouple 
Typical Performance of 12 PDQ30 Units; 0°C  
 (Note 1)
 
-1.5
-1.0
-0.5
0.0
0.5
1.0
1.5
0
5
10
15
20
Channel
E
rro
r   ( °
C
 )
 
Note 1:  Assumes 16384 oversampling applied, CMV = 0.0V, 60 minute warm-up, still environment, and 25°C ambient temperature. 
Excludes thermocouple error.   TC
IN
 = 0.0 °C 
 
Accessories and Cables
 
Termination Board (TB-100): Termination board with screw terminals for access to DaqBoard/3000 Series I/O.   
The terminal board connects to the DaqBoard’s 68-pin connector via a CA-G55, CA-56, or CA-56-6 cable. 
Rack Mount Kit (Rack3) Kit for mounting the TB-100 termination board to a rack. 
DBK215 Termination Module:  Includes 16 BNC connectors and internal screw-terminals. DBK215 connects to 
the DaqBoard’s 68-pin connector via a CA-G55, CA-56, or CA-56-6 cable. 
PDQ30 Analog Input Expansion Module:  Adds 48 SE [or 24 DE] channels to a DaqBoard/3000 Series board.  
Characteristics of the expansion channels are identical to those of the onboard channels.  PDQ30 connects to 
the 3000 Series board via HDMI cable CA-266-3, or CA-266-6.  PDQ30 cannot be connected to a 
DaqBoard/3006.
 
CA-G55 68-conductor ribbon expansion cable.  Can be used to connect a DaqBoard/3000 Series board to a 
TB-100 or DBK215.  Cable length: 3 ft. 
CA-G56 68-conductor shielded expansion cable.  Can be used to connect a DaqBoard/3000 Series board to a 
TB-100 or DBK215.  Cable length: 3 ft. 
CA-G56-6:  68-conductor shielded expansion cable.  Can be used to connect a DaqBoard/3000 Series board to a 
TB-100 or DBK215.  Cable length: 6 ft. 
CA-266-3:  HDMI cable.  Can be used to connect a PDQ30 expansion module to a DaqBoard/3000 Series board.  
Cable length: 3 ft.  PDQ30 cannot be connected to a DaqBoard/3006. 
CA-266-6:  HDMI cable.  Can be used to connect a PDQ30 expansion module to a DaqBoard/3000 Series board.  
Cable length: 6 ft.  PDQ30 cannot be connected to a DaqBoard/3006.