295
12.3.56  A12104: Immediate Value Expected
Type:
Error
Description:
The immediate addressing mode is expected at that position.
Usually, this error message is generated when the mask
specified in a BRCLR or BRSET instruction is not preceded by
the immediate character (#).
Example:
maskValue: EQU $40
         BSCT
var:     DS.B 1
CodeSec: SECTION
entry:
         LDD   #4567
         BRCLR var, maskValue, endCode
         …
endCode:
         END
Tip:
Insert the immediate character (#) at the requested position to
change to the immediate addressing mode.
Example:
maskValue: EQU $40
         BSCT
var:     DS.B 1
CodeSec: SECTION
entry:
         LDD   #4567
         BRCLR var, #maskValue, endCode
         …
endCode:
         END