Multiple MVME187s may be configured into a single VME card
cage. In general, hardware multiprocessor features are supported.
cage. In general, hardware multiprocessor features are supported.
GCSR Location Monitor Register
Other MPUs on the VMEbus can interrupt, disable, communicate
with and determine the operational status of the RISC processor(s).
One register of the GCSR set includes four bits which function as
location monitors to allow one MVME187 processor to broadcast a
signal to other MVME187 processors, if any. All eight GCSR
registers are accessible from any local processor as well as from the
VMEbus.
with and determine the operational status of the RISC processor(s).
One register of the GCSR set includes four bits which function as
location monitors to allow one MVME187 processor to broadcast a
signal to other MVME187 processors, if any. All eight GCSR
registers are accessible from any local processor as well as from the
VMEbus.
Ethernet LAN (+12 Vdc) Fuse
The MVME187 provides +12 Vdc power to the Ethernet LAN
transceiver interface through a 1-amp fuse (F2) located on the
MVME187. The
transceiver interface through a 1-amp fuse (F2) located on the
MVME187. The
+12V
LED lights when +12 Vdc is available. The
fuse is socketed and is located adjacent to diode
CR1
near
connector P1. If the Ethernet transceiver fails to operate, check the
fuse. When using the MVME712M transition module, the yellow
LED (DS1) on the MVME712M front panel lights when LAN power
is available, indicating that the fuse is good.
fuse. When using the MVME712M transition module, the yellow
LED (DS1) on the MVME712M front panel lights when LAN power
is available, indicating that the fuse is good.