 3 Functional Description
22
   
Watchdog Timers
The Harrier ASIC contains two Watchdog timers, WDT0 and WDT1. Each timer is functionally 
equivalent but independent. These timers continuously decrement until they reach a count of 0 
or are reloaded by software. The time-out period is programmable from 1 microsecond up to 32 
minutes. If the timer count reaches 0, a timer output signal is asserted. The output of Watchdog 
Timer 0 is routed to an MPIC interrupt. The output of Watchdog Timer 1 is connected to the 
Harrier AUXRST, which will generate RESETOUT_L.
Following a Harrier device reset, WDT0 is enabled with a default time-out of 8 seconds and 
WDT 1is enabled with a default time-out of 16 seconds. Each timer must be disabled or 
reloaded by software to prevent a time-out. Software may reload a new timer value or force the 
timer to reload a previously loaded value. To disable or load/reload a timer requires a two step 
process.
Interrupt Routing and Generation
External interrupts routed to the Harrier MPIC include the four PCI interrupts INTA#-INTD#, four 
host board interrupts from PMC connector P14, and the output from the watchdog timers. The 
PrPMC800/800ET has the ability to generate any one of the PCI interrupts INTA#-INTD# by 
using the Harrier Generic Outbound Doorbell register or the I2O controller. The desired PCI 
interrupt is selected by programming the PCI Interrupt Mapping bits in the Harrier Bridge PCI 
Control and Status register.
Asynchronous Serial Port
The PrPMC800/800ET
 
module provides a two-wire asynchronous serial interface (TXD and 
RXD) for use as a serial debug port. UART0 in the Harrier ASIC provides the 16550 compatible 
UART controller. The UART0 port SIN0 and SOUT0 signals are wired to an external RS-232 
transceiver which interfaces to the 2mm debug header and the P14 connector. An onboard 
1.8432 MHz oscillator provides the baud rate clock for the UART.
Clock Generator
The PrPMC800/800ET module clock generator uses a Z9972 PLL clock driver to provide the 
clocks for the processor, the Harrier ASIC and the SDRAMs. All clocks are referenced to the 
PCI clock input on PMC connector P11. The PrPMC800/800ET supports the PPC-to-PCI clock 
ratios listed in the following table. Onboard logic uses the state of the PMC M66EN pin to 
determine whether the maximum PCI clock frequency will be 33 MHz or 66 MHz.
Table 3-3. PPC to PCI Clock Ratios
M66EN Pin
PPC Clock
Frequency
(MHz)
PCI Clock
Frequency
(MHz)
Ratio
(PPC:PCI)
Harrier PCI 
Clock Divisor 
(N)
Low
100
33.33
3:1
12
High
100
66.67
3:2