3-40
Computer Group Literature Center Web Site
PCCchip2
3
Printer FAULT Interrupt Control Register
IL2-IL0
These three bits select the interrupt level for the printer 
FAULT. Level 0 does not generate an interrupt. 
ICLR
In edge-sensitive mode, writing a logic 1 to this bit clears 
the INT status bit. This bit has no function in level-
sensitive mode. This bit is always read as zero. 
IEN
When this bit is high, the interrupt is enabled. The 
interrupt is disabled when this bit is low. 
INT
When this bit is high, a printer FAULT interrupt is being 
generated at the level programmed in IL2-IL0 (if 
nonzero). 
E/L*
When this bit is high, the interrupt is edge-sensitive. The 
interrupt is level-sensitive when this bit is low. 
PLTY
When this bit is low, interrupt is activated by a falling 
edge/low level of the PRFAULTI* pin. 
When this bit is high, interrupt is activated by a rising 
edge /high level of the PRFAULTI* pin. 
Note that if this bit is changed while the E/L* bit is set (or 
is being set), a FAULT interrupt may be generated. This 
can be avoided by setting the ICLR bit during write cycles 
that change the E/L* bit. 
ADR/SIZ
$FFF42031 (8 bits)
BIT
23
22
21
20
19
18
17
16
NAME
PLTY
E/L*
INT
IEN
ICLR
IL2
IL1
IL0
OPER
R/W
R/W
R
R/W
C
R/W
R/W
R/W
RESET
0 PL
0 PL
0 PL
0 PL
0 PL
0 PL
0 PL
0 PL