Soyo SY-K7ADA User Manual

Page of 90
BIOS Setup Utility
SY-K7ADA
68
Disabled
Default
HDD Power
Down
1-15 Min
When the set time has
elapsed, BIOS sends a
command to the HDD to
power down. This turns off
the HDD motor.
Some older
model HDDs
may not support
this advanced
function.
Suspend Mode Disabled
Default
1 Min -
1 Hour
In Suspend mode, the CPU
stops completely (no
instructions are executed.)
Only an SL-
Enhanced (or
SMI) CPU can
enter this mode.
Power Management Controls (Continued)
Power
Management
Controls
Setting
Description
Note
Instant-off
Default
Soft-Off by
PWR-BTTN
Delay 4
Sec.
Turns off the system power 4
seconds after pushing the power
button.
Disabled
Default
Enabled
If enabled any PCI interrupt will
wake up the system.
Wake up \
Power On by
PCI Card
Disabled
Default
Enabled
An input signal on the serial Ring
Indicator (RI) line (in other words,
an incoming call on the modem)
awakens the system from a soft off
state.
Wake up \
Power by Ring
Disabled
Default
Enabled
If enabled this item can use A USB
device to wake up system from S3-
S5.
USB Dev
Wake up
From S3-S5
Disabled
The system ignores the alarm.
Default
Resume by
Alarm
Enabled
Set alarm to power on the system
by the date (1-31) or time
(hh:mm:ss). If the date is set to [0],
the system will self-power on by
alarm everyday at the set time.