en | Introduction
RAID Subsystem DVA-08K | Installation Manual
F.01U.027.797 | V2 | 2008.08
Bosch Security Systems
2.5
Hot-Swappable Components
2.5.1
Hot-Swap Capabilities
The subsystem comes with a number of hot-swappable components. A hot-swap component 
is one that can be exchanged while the subsystem is still online without affecting the opera-
tional integrity of the subsystem. These components should only be removed from the subsys-
tem when they are being replaced. At no other time should these components be removed 
from the subsystem.
2.5.2
Components
The following components are all hot-swappable:
Power supply units (PSUs)
Cooling fan modules
Hard drives
BBU module
2.5.3
Normalized Airflow
Proper subsystem cooling is referred to as “normalized” airflow. Normalized airflow ensures 
the sufficient cooling of the subsystem and is only attained when all components are properly 
installed. Therefore, a failed component should only be hot-swapped when a replacement is 
available. If a failed component is removed but not replaced, permanent damage to the sub-
system can result.