Crown CT 8150 User Manual

Page of 28
CT Power Amplifiers
page 11
CT Power Amplifiers
Operation Manual
7 Back Panel
1. AC Power Inlet
•  Standard IEC type 320 inlet for detachable 
connector
•  100-240V 
2. Reset Button/Breaker
•  Push button switch
•  Resets the circuit breaker that protects the power 
supply
•  A circuit breaker located near the IEC power inlet 
protects the amplifier from excessive AC current 
draw.
3. Auxiliary Connector
•  3-pin Phoenix type connector
•  Allows for amp to be placed in DEEP SLEEP 
mode and monitoring of AMP STATUS           
(see Section 10.2)
4. Amp Configuration DIP Switches (see Amp 
Status/Configuration in section 10.2)
•  Switches 1-5 turn specific settings on and off: 
 
-70 Hz HPF (High Pass Filter 
   
- see Section 8.1)
 -Auto-Standby
 
-Amp Status
 
-Green Power (See Section 9.2)
 -Limiter
•  Switches 6-12 sends input channel audio signal 
to corresponding output channel and adjacent 
output channel. In four channel model, switch 
6-9 are non-functional, (see section 11)
5. Amp Input Connectors
•  3-pin block connector can be used per input
•  High impedance balanced
6. Channel Level Controls
•  One 21-position detented rotary attenuator per 
channel
•  Attenuation range from -100dB to 0dB
7. Output Speaker Connector
•  4-pin Barrier block type per two channels                    
(2-Pin or 8-Pin Phoenix can be used)
1
2
3
4
5
6
7
5
6