Crown CT 8150 User Manual

Page of 28
Operation Manual
CT Power Amplifiers
page 18
17 AC Power Draw and Thermal Dissipation
ComTech DriveCore 4150
Load
Watts in 
Watts 
out
120VAC
Watts
Dissipated
Watts in
Watts out
240VAC
Watts
Dissipated
Thermal Dispation
Line
Current
Watts Out 
Per 1A Line 
Current
Line 
Current
Watts Out 
Per 1A Line 
Current
btu/hr
kcal/hr
Idle (Deep Sleep)
-
0.9
<0.1
1.00
0.90
<0.1
1
3.41
0.86
Idle (Auto Standby)
-
11.9
0.35
11.90
10.90
0.28
15.8
53.88
13.57
Idle (Awake)
-
17.5
0.60
17.50
16.50
0.37
25
85.25
21.48
Idle (Green Power
-
9.7
0.25
-
9
0.20
-
-
-
1/8th Power Pink 
Noise
8
98
63
1.90
33
36
96
63
1.20
53
33
121.06
30.49
6
102
63
2.10
30
40
120
63
1.25
50
39
134.70
33.93
4
115
63
2.20
28
53
105
63
1.32
48
42
179.03
45.10
1/3rd Power Pink 
Noise
8
225
167
3.95
42
58
230
167
2.45
68
63
214.83
54.12
6
230
167
4.00
42
63
244
167
2.55
65
77
262.57
66.14
4
240
167
4.15
40
73
248
167
2.60
64
81
276.21
69.58
1/8th Power Sine
8
95
63
1.80
35
32
94
63
1.08
58
31
109.12
27.49
6
96
63
1.82
34
34
95
63
1.09
57
33
114.24
28.78
4
100
63
1.89
33
38
99
63
1.13
55
37
127.88
32.21
1/3rd Power Sine
8
222
167
3.89
43
55
221
167
2.34
71
54
188.23
47.42
6
227
167
3.98
42
60
225
167
2.37
70
58
205.96
51.88
4
237
167
4.12
40
70
235
167
2.48
67
68
238.02
59.96
AC Power Draw and Thermal Disspation:
Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.                                                             
Typical line impedance used.                                                                                                               
Measurements made with 120/240 VAC mains.                                                                                                     
Data based on all channels driven at 8 Ohms.