Contec SPI-8450-LLVA User Manual

Page of 129
CHAPTER 6 - RAID Controller
                                                                                                                                                   
 
66
SPI-8450-LLVA
Offline: Drives that are NOT identified as “bad” may be taken offline if part of a Striping or
Spanning array containing a “bad” drive. These drives do NOT need to be replaced,
however.
S.M.A.R.T. Status: Indicates whether attached hard drive implements Self-Monitoring
Analysis & Reporting Technology to predict drive failure
Size: Indicates capacity of individual drive
Location: Shows physical location of drive. Indicates on which IDE channel (1 or 2), and
whether drive is Master or Slave on cable. This allows user to identify drives for
removal/replacement.
Mapping: Indicates physical parameters of drive (cylinders, heads, sectors)
Timing: Shows selection of drive timing (directly related to burst speed) based on type of drive
and cable used.
6.4.7 Using Options Window
Clicking on the Options tab reveals the Options Window. Array administrators can customize
the FastCheck™ Monitoring Utility in four major areas: Notification, Array Synchronization
Scheduling, setting Password, Desktop Appearance. Most options relate to 
Mirroring arrays
(RAID 1).