Contec SPI-8451-LLVA User Manual

Page of 123
6. RAID Controller 
 
 
 
52 
SPI-8451-LLVA, SPI-8452-LLVA, SPI-8451-LVA 
12.  Press [Enter] and confirm that the data will be copied on to the selected drive.    All data on the 
replacement drive will be written over with mirrored information from the array drive. 
 
A progress bar will appear as below. 
Please Wait While Duplicating The Image 
                                                                                                            10% Complete 
13.  Once the rebuild process is complete, the user will be asked to reboot the system. 
 
Viewing Controller Settings 
The Controller Configuration <6> menu selection allows you to enable or disable the RAID controller 
BIOS from halting (the default) if it detects an error on boot up.    You may also view the system 
resources (Interrupt and I/O port address) of FastTrak’s data channels. 
 
FastBuild (tm) Utility 1.xx (c) 1996-2001 Promise Technology, Inc. 
 
[ Adapter Configuration - Options ] 
 
               
Halt On Error: 
Enable 
 
 
 
[ System Resources Configuration ] 
    Channel 1 (IDE1)  
Interrupt : A  I/O    Port : FFF0 
    Channel 2 (IDE2)  
Interrupt : A  I/O Port    : FFA8 
 
[ Keys Available ] 
[
←, →, Space] Change Option      [ESC] Exit 
 
Halting RAID controller BIOS on Boot up Errors 
The [Adapter Configuration – Options] section allows you to enabled or disable RAID controller to Halt 
operation at the BIOS startup screen should an error be detected.    This is the only option that can be 
changed on this screen. 
Viewing RAID Controller System Resource 
The [System Resources Configurations] section of this submenu displays the PCI slot interrupt and port 
address used by the RAID controller.    The resources used are determined by the SPI-8451-LLVA PCI 
PnP BIOS for the PCI device resides. 
In the rare case that there is a resource conflict, refer to the SPI-8451-LLVA BIOS documentation on 
changes on resources allocated to the RAID Controller.