Sun Microsystems 6.0005E+11 User Manual
Product Overview
1-7
1
1.3 Internal Options
Table 1-2
Internal Options for the Ultra Enterprise Server Systems
Option
Enterprise 6000
Enterprise 5000/4000 Comments
CPU/Memory
boards, SBus
I/O boards,
and Graphics
I/O boards
boards, SBus
I/O boards,
and Graphics
I/O boards
16 total per system
8 total per system
Each slot can accept any of these three types of boards:
CPU/Memory board, SBus I/O board, and Graphics I/O
board. Combinations can vary. One CPU/Memory board
becomes the system master automatically. Jumper changes
are not needed. For easier I/O boards cabling,
CPU/Memory boards can be installed in the front and I/O
boards in the rear of the Enterprise system.
CPU/Memory board, SBus I/O board, and Graphics I/O
board. Combinations can vary. One CPU/Memory board
becomes the system master automatically. Jumper changes
are not needed. For easier I/O boards cabling,
CPU/Memory boards can be installed in the front and I/O
boards in the rear of the Enterprise system.
Disk boards
2 per system (must
use slot 15 if only 1
is installed)
use slot 15 if only 1
is installed)
4 per system
Can be installed only in slot 14 and slot 15 in the
Enterprise 6000 system.
For easier Disk boards cabling, CPU/Memory boards can
be installed in the front and Disk boards in the rear of the
Enterprise system.
Enterprise 6000 system.
For easier Disk boards cabling, CPU/Memory boards can
be installed in the front and Disk boards in the rear of the
Enterprise system.
UltraSPARC
modules
modules
30
14
0-2 modules on each CPU/Memory board.
Memory
modules
modules
0, 8, or 16 SIMMs
per CPU/Memory
board
per CPU/Memory
board
0, 8, or 16 SIMMs
per CPU/Memory
board
per CPU/Memory
board
SIMM sizes are 8, 32, or 128 Mbyte DRAM. Do not mix
sizes within the same bank.
Add 8 SIMMs at a time. Install SIMMs in all bank 0 sockets
first on each CPU/Memory board, from the lowest slot to
the highest. Once bank 0 is full, install remaining SIMMs in
bank 1 sockets in the same order.
sizes within the same bank.
Add 8 SIMMs at a time. Install SIMMs in all bank 0 sockets
first on each CPU/Memory board, from the lowest slot to
the highest. Once bank 0 is full, install remaining SIMMs in
bank 1 sockets in the same order.
SBus cards
15 per system
7 per system
0-3 cards per SBus I/O board, 0-2 cards per Graphics I/O
board.
board.
Graphics (UPA)
cards
cards
4 per system
4 per system
0-1 card per Graphics I/O board.
SCSI tray
CD-ROM and tape
drive
drive
CD-ROM and tape
drive
drive
SCSI tray takes removable-media drives only. One SunCD 4
is standard equipment per system. One optional tape drive
is supported in the SCSI tray.
is standard equipment per system. One optional tape drive
is supported in the SCSI tray.
Disk tray
The Enterprise 6000 system cabinet can hold 0-3 trays; the Enterprise 5000 system cabinet can hold 0-4.
The expansion cabinet can hold 1-8 trays; each disk tray holds up to six 5 1/4-inch form factor disk
drives. Refer to documentation that comes with the disk trays and expansion cabinet.
The expansion cabinet can hold 1-8 trays; each disk tray holds up to six 5 1/4-inch form factor disk
drives. Refer to documentation that comes with the disk trays and expansion cabinet.
Multi-tape tray
or tape library
or tape library
The Enterprise 6000/5000 system cabinet can hold 1 multi-tape backup tray or tape library.
The expansion cabinet can hold 1 or 2 multi-tape trays or tape libraries. Tape trays hold up to four
8 mm tape drives. Refer to documentation that comes with the tape trays and expansion cabinet.
The expansion cabinet can hold 1 or 2 multi-tape trays or tape libraries. Tape trays hold up to four
8 mm tape drives. Refer to documentation that comes with the tape trays and expansion cabinet.